OMAP3: mcx: read hot-water-button after reset
Detect hot-water-button to start a differnt image.
Signed-off-by: Stefano Babic <sbabic@denx.de>
CC: Tom Rini <trini@ti.com>
diff --git a/include/configs/mcx.h b/include/configs/mcx.h
index 9d552a0..ad7078c 100644
--- a/include/configs/mcx.h
+++ b/include/configs/mcx.h
@@ -30,6 +30,7 @@
#define MACH_TYPE_MCX 3656
#define CONFIG_MACH_TYPE MACH_TYPE_MCX
+#define CONFIG_BOARD_LATE_INIT
#define CONFIG_SYS_CACHELINE_SIZE 64
@@ -140,6 +141,7 @@
#define CONFIG_MTD_PARTITIONS
#define CONFIG_MTD_DEVICE
#define CONFIG_CMD_MTDPARTS
+#define CONFIG_CMD_GPIO
#undef CONFIG_CMD_FLASH /* flinfo, erase, protect */
#undef CONFIG_CMD_FPGA /* FPGA configuration Support */