| .. SPDX-License-Identifier: GPL-2.0+ |
| |
| FastBoot Version 0.4 |
| ==================== |
| |
| The fastboot protocol is a mechanism for communicating with bootloaders |
| over USB. It is designed to be very straightforward to implement, to |
| allow it to be used across a wide range of devices and from hosts running |
| Linux, Windows, or OSX. |
| |
| Basic Requirements |
| ------------------ |
| |
| * Two bulk endpoints (in, out) are required |
| * Max packet size must be 64 bytes for full-speed and 512 bytes for |
| high-speed USB |
| * The protocol is entirely host-driven and synchronous (unlike the |
| multi-channel, bi-directional, asynchronous ADB protocol) |
| |
| |
| Transport and Framing |
| --------------------- |
| |
| 1. Host sends a command, which is an ascii string in a single |
| packet no greater than 64 bytes. |
| |
| 2. Client response with a single packet no greater than 64 bytes. |
| The first four bytes of the response are "OKAY", "FAIL", "DATA", |
| or "INFO". Additional bytes may contain an (ascii) informative |
| message. |
| |
| a. INFO -> the remaining 60 bytes are an informative message |
| (providing progress or diagnostic messages). They should |
| be displayed and then step #2 repeats |
| |
| b. FAIL -> the requested command failed. The remaining 60 bytes |
| of the response (if present) provide a textual failure message |
| to present to the user. Stop. |
| |
| c. OKAY -> the requested command completed successfully. Go to #5 |
| |
| d. DATA -> the requested command is ready for the data phase. |
| A DATA response packet will be 12 bytes long, in the form of |
| DATA00000000 where the 8 digit hexidecimal number represents |
| the total data size to transfer. |
| |
| 3. Data phase. Depending on the command, the host or client will |
| send the indicated amount of data. Short packets are always |
| acceptable and zero-length packets are ignored. This phase continues |
| until the client has sent or received the number of bytes indicated |
| in the "DATA" response above. |
| |
| 4. Client responds with a single packet no greater than 64 bytes. |
| The first four bytes of the response are "OKAY", "FAIL", or "INFO". |
| Similar to #2: |
| |
| a. INFO -> display the remaining 60 bytes and return to #4 |
| |
| b. FAIL -> display the remaining 60 bytes (if present) as a failure |
| reason and consider the command failed. Stop. |
| |
| c. OKAY -> success. Go to #5 |
| |
| 5. Success. Stop. |
| |
| |
| Example Session |
| --------------- |
| |
| .. code-block:: none |
| |
| Host: "getvar:version" request version variable |
| |
| Client: "OKAY0.4" return version "0.4" |
| |
| Host: "getvar:nonexistant" request some undefined variable |
| |
| Client: "OKAY" return value "" |
| |
| Host: "download:00001234" request to send 0x1234 bytes of data |
| |
| Client: "DATA00001234" ready to accept data |
| |
| Host: < 0x1234 bytes > send data |
| |
| Client: "OKAY" success |
| |
| Host: "flash:bootloader" request to flash the data to the bootloader |
| |
| Client: "INFOerasing flash" indicate status / progress |
| "INFOwriting flash" |
| "OKAY" indicate success |
| |
| Host: "powerdown" send a command |
| |
| Client: "FAILunknown command" indicate failure |
| |
| |
| Command Reference |
| ----------------- |
| |
| * Command parameters are indicated by printf-style escape sequences. |
| |
| * Commands are ascii strings and sent without the quotes (which are |
| for illustration only here) and without a trailing 0 byte. |
| |
| * Commands that begin with a lowercase letter are reserved for this |
| specification. OEM-specific commands should not begin with a |
| lowercase letter, to prevent incompatibilities with future specs. |
| |
| .. code-block:: none |
| |
| "getvar:%s" Read a config/version variable from the bootloader. |
| The variable contents will be returned after the |
| OKAY response. |
| |
| "download:%08x" Write data to memory which will be later used |
| by "boot", "ramdisk", "flash", etc. The client |
| will reply with "DATA%08x" if it has enough |
| space in RAM or "FAIL" if not. The size of |
| the download is remembered. |
| |
| "verify:%08x" Send a digital signature to verify the downloaded |
| data. Required if the bootloader is "secure" |
| otherwise "flash" and "boot" will be ignored. |
| |
| "flash:%s" Write the previously downloaded image to the |
| named partition (if possible). |
| |
| "erase:%s" Erase the indicated partition (clear to 0xFFs) |
| |
| "boot" The previously downloaded data is a boot.img |
| and should be booted according to the normal |
| procedure for a boot.img |
| |
| "continue" Continue booting as normal (if possible) |
| |
| "reboot" Reboot the device. |
| |
| "reboot-bootloader" Reboot back into the bootloader. |
| Useful for upgrade processes that require upgrading |
| the bootloader and then upgrading other partitions |
| using the new bootloader. |
| |
| "powerdown" Power off the device. |
| |
| "ucmd" execute any bootloader command and wait until it |
| finishs. |
| |
| "acmd" execute any bootloader command, do not wait. |
| |
| Client Variables |
| ---------------- |
| |
| The ``getvar:%s`` command is used to read client variables which |
| represent various information about the device and the software |
| on it. |
| |
| The various currently defined names are:: |
| |
| version Version of FastBoot protocol supported. |
| It should be "0.3" for this document. |
| |
| version-bootloader Version string for the Bootloader. |
| |
| version-baseband Version string of the Baseband Software |
| |
| product Name of the product |
| |
| serialno Product serial number |
| |
| secure If the value is "yes", this is a secure |
| bootloader requiring a signature before |
| it will install or boot images. |
| |
| all Provides all info from commands above as |
| they were called one by one |
| |
| Names starting with a lowercase character are reserved by this |
| specification. OEM-specific names should not start with lowercase |
| characters. |