ARM: zynq: DT: Add a fixed regulator for CPU voltage
To silence the warning
cpufreq_cpu0: failed to get cpu0 regulator: -19
from the cpufreq driver regarding a missing regulator,
add a fixed regulator to the DT.
Zynq does not support voltage scaling and the CPU rail should always be
supplied with 1 V, hence it is added in the SOC-level dtsi.
Signed-off-by: Soren Brinkmann <soren.brinkmann@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
diff --git a/arch/arm/dts/zynq-7000.dtsi b/arch/arm/dts/zynq-7000.dtsi
index fc5dd4d..326ab67 100644
--- a/arch/arm/dts/zynq-7000.dtsi
+++ b/arch/arm/dts/zynq-7000.dtsi
@@ -21,6 +21,7 @@
reg = <0>;
clocks = <&clkc 3>;
clock-latency = <1000>;
+ cpu0-supply = <®ulator_vccpint>;
operating-points = <
/* kHz uV */
666667 1000000
@@ -44,6 +45,15 @@
reg = < 0xf8891000 0x1000 0xf8893000 0x1000 >;
};
+ regulator_vccpint: fixedregulator@0 {
+ compatible = "regulator-fixed";
+ regulator-name = "VCCPINT";
+ regulator-min-microvolt = <1000000>;
+ regulator-max-microvolt = <1000000>;
+ regulator-boot-on;
+ regulator-always-on;
+ };
+
amba {
compatible = "simple-bus";
#address-cells = <1>;