| SiFive PWM controller |
| |
| Unlike most other PWM controllers, the SiFive PWM controller currently only |
| supports one period for all channels in the PWM. All PWMs need to run at |
| the same period. The period also has significant restrictions on the values |
| it can achieve, which the driver rounds to the nearest achievable period. |
| PWM RTL that corresponds to the IP block version numbers can be found |
| here: |
| |
| https://github.com/sifive/sifive-blocks/tree/master/src/main/scala/devices/pwm |
| |
| Required properties: |
| - compatible: Should be "sifive,<chip>-pwm" and "sifive,pwm<version>". |
| Supported compatible strings are: "sifive,fu540-c000-pwm" for the SiFive |
| PWM v0 as integrated onto the SiFive FU540 chip, and "sifive,pwm0" for the |
| SiFive PWM v0 IP block with no chip integration tweaks. |
| - reg: physical base address and length of the controller's registers |
| - clocks: Should contain a clock identifier for the PWM's parent clock. |
| - #pwm-cells: Should be 3. |
| - interrupts: one interrupt per PWM channel |
| |
| Examples: |
| |
| pwm: pwm@10020000 { |
| compatible = "sifive,fu540-c000-pwm", "sifive,pwm0"; |
| reg = <0x0 0x10020000 0x0 0x1000>; |
| clocks = <&tlclk>; |
| interrupt-parent = <&plic>; |
| interrupts = <42 43 44 45>; |
| #pwm-cells = <3>; |
| }; |