| PHY nodes for Aquantia devices. |
| |
| This text describes properties that are applicable to Aquantia PHY nodes in |
| addition to the bindings in phy.txt. |
| |
| Aquantia PHYs allow some flexibility in the way they are wired in a system, |
| they allow MDI pins to be reversed, LEDs linked up in different weays, have an |
| I2C slave interface that can be used for debug. Normally the configuration |
| corresponding to these is driven by the PHY firmware with the downside that |
| a custom firmware is needed for each integration of a PHY. |
| Several optional bindings are defined that allow these configuration points to |
| be driven by the PHY driver and reduce dependency on specific FW versions. |
| |
| Optional properties: |
| mdi-reversal: 0 or 1 indicating that reversal must be disabled/enabled. |
| Firmware default is used if the property is missing. |
| smb-addr: I2C/SMBus address to use, firmware default is used if the property |
| is missing. |
| |
| Example node: |
| phy@00 { |
| reg = <0x00>; |
| mdi-reversal = <1>; |
| smb-addr = <0x25>; |
| }; |